Dynamic load management (DLM)
The Dynamic load management screen allows you to enable or disable the Dynamic load management (DLM) functionality. When the functionality is enabled, the screen allows you to:
pair the charging station with a metering device, which can control your charging speeds,
set all DLM related settings.
Open the Device configuration screen and select Dynamic load management.
The Dynamic load management screen opens.
By default, the DLM functionality is disabled.
To enable it, toggle the switch.
When DLM is enabled, the options for the currently selected metering device are displayed; if no device has been selected, Core Load Guard options are shown by default.
If the DLM had previously been set up and the functionality was merely disabled, re-enabling it will display the screen with the settings that were configured before it was disabled. The same applies if a different metering device was selected and the charging station was not restarted to apply the changes.
The options displayed on the screen depend on the selected device in the Metering device field, and may additionally vary based on other screen settings.
1 – Toggle to enable/disable the dynamic load management (DLM) functionality.
When the DLM functionality is enabled, additional options appear below; when disabled, the options are hidden.
2 – Select the type of metering device you are connecting for the DLM functionality:
– Core Load Guard
– RS-485 meter
The options that follow on the screen depend on the selected “Metering device“ type.
3 – Tap to open a step-by-step guide to connect your Load Guard. In the guide, swipe left/right between the guide screens.
Once the Load Guard is connected, the guide title is changed into “How to replace your Load Guard”.
4 – State of your connection to the Load Guard / direct connected RS-485 meter and its detailed description. Possible statuses:
– Connected
– No connection
– Authentication failed
– Connection lost
– Update in progress
5 – Building limits section displays maximum current limitations for the DLM.
DLM screen – INCH Core Load Guard
Once the Load Guard is connected with the charging station and Core LoadGuard is selected in the Metering device field, the following options of the Dynamic load management screen appear. Below is an example screen that may vary depending on other settings on the screen.
1 – Toggle to enable/disable the dynamic load management (DLM) functionality.
When the DLM functionality is enabled, additional options appear below; when disabled, the options are hidden.
2 – Core Load Guard is selected as the type of metering device for the DLM functionality.
3 – Tap to open a step-by-step guide to replace your Load Guard. In the guide, swipe left/right between the guide screens.
4 – State of your connection to the Load Guard and its detailed description. Possible statuses:
– Connected
– No connection
– Authentication failed
– Connection lost
– Update in progress
5 – Serial number of the Load Guard
6 – Select the type of connection, through which the charging station will receive data from the Load Guard:
– Current transformers
– RS-485 meter (electricity meter* connected to the Load Guard via RS-485)
– Over TIC port (electricity meter* connected to the Load Guard via the TIC port)
– Over P1 port (electricity meter* connected to the Load Guard via the P1 port)
* For more information, refer to the DLM functionality description of the INCH Core charging station.
7 – Real-time measurements obtained from the connected Load Guard.
8 – Building limits section displays maximum current limitations for the DLM.
DLM screen – External RS-485 meter
Once an external meter is connected via RS-485 physical interface with the charging station and RS-485 meter is selected in the Metering device field, the following options of the Dynamic load management screen appear. Below is an example screen that may vary depending on other settings on the screen.
1 – Toggle to enable/disable the dynamic load management (DLM) functionality.
When the DLM functionality is enabled, additional options appear below; when disabled, the options are hidden.
2 – RS-485 Meter is selected as the type of metering device for the DLM functionality.
3 – Select a type of the meter that is connected to the charging station via the RS-485 interface.
4 – When the type of the RS-485 meter is specified in the Meter type field, the Advanced settings for the selected meter will be displayed.
Tap on Advanced settings to collapse/expand the settings.
5 – State of your connection to the metering device / input and its detailed description. Possible statuses:
– Connected – Metering connection is successfully established.
– Connection failed - Check your meter’s connection and configuration.
– Invalid values – Measurements received from the metering device are not valid.
6 – Real-time measurements obtained from the connected meter.
7 – Building limits section displays maximum current limitations for the DLM.
Warning! Before installing, wiring, handling or accessing the charging station in any way, make sure to read, understand and follow the Safety Guidelines.
Any graphic material provided in this documentation library is subject to variation and may not reflect the most recent updates or changes due to ongoing development and the implementation of new features.
Owing to periodic improvements of our products, the supplied products can differ in some details from the information stated in this documentation library. The information is subject to alteration without notice.
The English version of this documentation is the official and authoritative source of information. We make every effort to ensure that translations are accurate and clear; however, we do not accept responsibility for any errors, omissions, or misinterpretations in translated versions. In case of discrepancies, the English version will take precedence.