DEVICE DIAGNOSTICS
The Device diagnostics screen allows you to review the general diagnostics information of the charging station that you are connected to. From this screen, you can also open the event log, update firmware, or manually disable/enable charging.
Â
To open the Device diagnostics screen, follow corresponding instructions according to the mode, in which your station is currently operating.
Swipe up the bottom handle on the Dashboard screen.
Tap on Diagnostics.
Scroll down on the Configuration screen.
Tap on Diagnostics.
Â
Â
Â
1 – Name of the charging station you are connected to.
2 – Model of the charging station you are connected to.
3 – Serial number of the charging station you are connected to.
4 – EVSE code of charging station you are connected to.
The code acts as a unique identifier of the charging station in a network and can usually be edited.
5 – Temperature readings for circuit boards inside the charging station.
6 – Date of manufacturing of the charging station.
7 – Current level of access for accessing the charging station’s configuration settings.
8 – Trigger manual restart of the charging station (a dialog opens).
9 – Disable/enable charging at the charging station (a dialog opens).
10 – Firmware version.
11 – Tap to open the Firmware update dialog and check if a new firmware version is available.
12 – Tap to open the Firmware update dialog and manually choose an update file from your smartphone’s local storage.
13 – Reset the charging station’s configuration settings to factory default.
14 – (COMING SOON) Tap to export the charging station’s current configuration as a file.
15 – (COMING SOON) Tap to import a configuration file to apply to the currently connected charging station.
16 – Set event logging level:
- Default
- Debug
If you are performing troubleshooting, you can change the logging level to a more detailed setting. This change will last for 24h, after which it will automatically reset to default.
17 – (COMING SOON) Export the technical log.
Â
Warning! Before installing, wiring, handling or accessing the charging station in any way, make sure to read, understand and follow the Safety Guidelines.
Any graphic material provided in this documentation library is subject to variation and may not reflect the most recent updates or changes due to ongoing development and the implementation of new features.
Owing to periodic improvements of our products, the supplied products can differ in some details from the information stated in this documentation library. The information is subject to alteration without notice.
The English version of this documentation is the official and authoritative source of information. We make every effort to ensure that translations are accurate and clear; however, we do not accept responsibility for any errors, omissions, or misinterpretations in translated versions. In case of discrepancies, the English version will take precedence.