Technical datasheet

C_in_Hexagone_Small.png

Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C).

Electrical characteristics

Single-phase device

Input

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Output

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Three-phase device

Input

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Output

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Types of system earthing

TN, TT

Rated impulse withstand voltage (Uimp)

2500 V – OVC II (4000 V and OVC III is achieved with installed SPD)

Rated insulation voltage (Ui)

230/400 V

Rated current of each circuit (Inc)

32 A

Rated peak withstand current (Ipk)

4500 A

Rated conditional short-circuit current of assembly (Icc)

3000 A

Rated diversity factor (RDF)

  • 1 (without load control),

  • 0 to 1 (with proper setup of load control)

Device power consumption

10–15 W (highest measured value of full configuration)

Environmental characteristics

Ingress protection

IP56

Impact protection

IK10

Protection class

Class I equipment

Pollution degree

Pollution Degree 3

Electromagnetic compatibility (EMC)

  • EMC emissions: Class B (residential)

  • EMC immunity: Class A (other than residential)

Frequency bands and radio power

Wi-Fi

Frequency band: 2.4 GHz 

Transmitting power: up to 20.5 dBm (adjustable)

Sub-GHz 

Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz

Transmitting power: 14 dBm

RFID module

Frequency band: 13.56 MHz (HF)

Transmitting power: up to 8 dBm

(ISO 14443 and ISO 15693)

Other classification and characteristics

AEVCS

Assembly intended for charging stations for electric vehicles

Installation location

Indoor and Outdoor

Mounting method

Stationary equipment, Wall-mounted assembly

Location accessibility

Location with restricted access or non-restricted access

Mechanical resistance

Medium/High

Installation

Must be performed by qualified personnel

Operation

Allowed to ordinary persons

Electrical installation protection

  • Short-circuit protective device(s):
    Appropriate MCB or fuse must be part of electrical installation, installed upstream of the charging station.

  • Protection against electric shock:
    Appropriate RCD must be part of electrical installation, installed upstream of the charging station. 

Dimensions

Dimensions of assembled charging station (in mm)

image-20240229-135419.png

Main unit + Dock

257 × 273 × 115 (W × H1 × D)

Main unit + Output socket + Dock

257 × 401 × 115 (W × H2 × D)

Main unit + Output socket shutter + Dock

257 × 413 × 120 (W × H2 × D)

Main unit + Output Cable + Dock

257 × 387 × 115 (W × H2 × D)
H2 - to the bottom of the cable gland with a spiral

Mass

Mass (assembled charging station)

3.4 kg to 7 kg
(depending on the configuration and cable length)

Temperature

Operational

-25 °C to +85 °C

Ambiental

-25 °C to +50 °C

Storage

-30 °C to +85 °C

 

 

 

 

Warning! Before installing, wiring, handling or accessing the charging station in any way, make sure to read, understand and follow the Safety Guidelines.
Any graphic material provided in this documentation library is subject to variation and may not reflect the most recent updates or changes due to ongoing development and the implementation of new features.
Owing to periodic improvements of our products, the supplied products can differ in some details from the information stated in this documentation library. The information is subject to alteration without notice.
The English version of this documentation is the official and authoritative source of information. We make every effort to ensure that translations are accurate and clear; however, we do not accept responsibility for any errors, omissions, or misinterpretations in translated versions. In case of discrepancies, the English version will take precedence.