INCH Lite User Manual
Table of Contents
- 1 Table of Contents
- 2 FOREWORD
- 2.1 General Information
- 2.1.1 Intended Use
- 2.2 Safety Information
- 2.2.1 Operation
- 2.2.2 Irregularity or Interference at Operation
- 2.2.3 Maintenance
- 2.2.4 Fire Safety Measures
- 2.2.5 Firefighting Measures
- 2.2.5.1 CHARGING STATION FIRE
- 2.2.5.2 Vehicle Fire
- 2.2.5.3 Battery Fire
- 2.2.6 Environmental Safety Measures
- 2.2.7 Correct Disposal of this Product
- 2.2.7.1 Information about WEEE Directive
- 2.3 Compliancy
- 2.4 Safety Risk Analysis
- 2.5 Design Considerations
- 2.5.1 Licenses
- 2.5.1.1 TRANSPORTATION
- 2.5.1.2 STORAGE
- 2.5.1.3 STACKING
- 2.5.1.4 Packaging
- 2.5.1 Licenses
- 2.1 General Information
- 3 PRODUCT DESCRIPTION
- 4 INSTALLATION PROCEDURE
- 5 OPERATION AND CHARGING PROCEDURE
- 6 Regular MAINTENANCE
- 7 TROUBLESHOOTING
FOREWORD
Etrel INCH LITE charging station has been designed and tested in accordance with current and past versions of international standards. The charging station is compliant with IEC 61851 (Part 1, Part 21-2, Part 22) international standard which defines conductive AC electric vehicle charging and supports Mode 3 charging for safe recharging of standard electric vehicle.
The system enables safe and simple EV charging for the user and gives a comprehensive oversight and control of the charging.
The manual contains the latest information at the time of purchase. Any unauthorized modification or tampering with the product may void the product warranty.
Etrel d.o.o. reserves the right to make changes to the product without further notice. Customer support department will assist with any further inquiries about the product.
Notes to the installer:
Carefully read the installation instructions before installing the station. Follow all the instructions and recommendations.
After the installation is completed, make sure to leave these instructions with the customer.
Notes to the customer:
Use the charging station only in accordance with instructions for use. Carefully read these instructions and make sure to keep them for further reference. Ensure that the charging station is installed by a licensed electrician.
Preparation of charging station installation site and installation are described in separate documents. In this document it is predisposed that charging station is installed properly and already working.
General Information
Intended Use
Etrel INCH LITE charging station is intended only for charging of electric vehicles and should not be used to charge other appliances or for any other purpose.
No flammable materials or liquids should be used or stored in the direct vicinity of the charging station.
The manufacturer accepts no responsibility for damage or injuries resulting from incorrect installation or inappropriate use of the product.
Different types of charging connectors and converters are available as a part of optional equipment to allow safe charging of any standard electric vehicle.
Safety Information
Operation
The device must be used in accordance with the instructions contained in this manual.
Do not operate charging station if there is visible damage to the unit or charging cable. Call manufacturer’s or reseller’s support department for advice how to proceed.
Do not put fingers into the charging connector.
Do not operate the charging station with wet hands.
The charging station manufacturer cannot be made liable for damage or injury caused by improper handling, installation, or use of the product.
Any usage of the product not covered in this document is not allowed and could cause injury or even death.
When the charging station without integral RCD device is installed, the proper RCD device should be installed in the main electrical cabinet.
When the charging station without integral overcurrent device is installed, the proper overcurrent device should be installed in the main electrical cabinet.
Irregularity or Interference at Operation
In the event of irregularities or interference in the operation of the device, immediately stop using the charging station and inform the charging station operator of the situation by phone number located on the housing or other place.
Maintenance
Charging station can be maintained and repaired by qualified personnel only.
Charging station’s power supply should always be switched off during the maintenance and repair.
Avoid hazardous risks. Only the manufacturer, an authorized service technician, or technically qualified personnel may replace damaged charging station or its components.
Fire Safety Measures
At the location of car charging, the fire hazards and thus the threats are increased during the process of charging. The overall design of our products is made on the basis assumption that the fault could occur on any element of the system. Either in the electrical wiring of power supply, in wiring or inside of the charging station, or in the car.
The enclosure and the assembly design of the charging station are made in such a way that the contact of the user to hazardous parts is not possible. In the event of fire, metal enclosure would constrain a fire and would not allow the propagation outside of the enclosure. Regarding the fire safety in all possible cases of installation, that are out of control of our company, several recommendations are listed:
The charger must be installed outside the hazardous area.
The installation of the charging station can be performed only by professional electrician and must comply with the installation manual and local installation rules.
Ensure that there is enough space to manoeuvre vehicles into their designated charging areas and that in event of fire the escape and rescue routes are not obstructed.
No flammable or combustible material should be stored within the charging area.
Provision of suitable portable fire extinguisher at the location of the charging station is proposed.
Firefighting Measures
CHARGING STATION FIRE
In the event of a charging fire, the usual rules in the event of an electrical cabinet fire apply. In case of fire please follow these steps:
In the event of a fire, immediately stop using the charging station and call the appropriate services (fire brigade).
If possible, disconnect the station from the power supply by pressing the fire protection switch (if present) or another switch responsible for cutting off the power supply to the station.
Retreat from fire area.
Extinguishing should be carried out with extinguishers intended for extinguishing electrical devices up to 1000 V.
Do not extinguish live electrical installations and devices with water!
The following is general information obtained from various sources. For detailed instructions on extinguishing fires of electric vehicles or their batteries, fire brigade have appropriate procedures already established.
Vehicle Fire
Vehicles, made of light metal, such as magnesium or aluminium, develop high temperatures above 1000 °C when burning. When extinguished with water such a high temperature evaporates it and can cause burning particles of distinctly white colour and high temperatures to fly around the vehicle. Extinguishing such vehicles requires great care in forming the water jet and in the amount of water.
If a burning vehicle is connected to a charging station, it is necessary to ensure that the charging station is in a voltage-free state by disconnecting the line from which it is supplied.
If firefighters are at the scene of a fire in less than half an hour, the battery usually does not ignite yet and the vehicle can be extinguished easier, and all extinguishing agents can be used. The general recommendations are mainly to use water and foam.
Battery Fire
In general, battery manufacturers, regardless of the type of battery, recommend water for successful extinguishing, although reactions may occur.
If the batteries catch fire, they will burn until they burn out completely. Another option is to immerse the batteries in water for at least half an hour. If the battery is not extinguished successfully, the fire will recur.
Environmental Safety Measures
When implementing protection measures, environmental protection must also be observed. For this reason, special care has been put into selection of the components and their compliance with the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS). This directive restricts use of hazardous materials in the manufacture of various types of electronic and electrical equipment.
The substances banned under RoHS are heavy metals, lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB), polybrominated diphenyl ethers (PBDE), and four different phthalates (DEHP, BBP, DBP, DIBP).
The restricted materials are hazardous to the environment and pollute landfills and are dangerous in terms of occupational exposure during manufacturing and recycling.
Another example of use of environmentally friendly materials in our products is compliance to REACH, which is a regulation of the European Union, adopted to improve the protection of human health and the environment from the risks that can be posed by chemicals. REACH regulation also promotes alternative methods for the hazard assessment of substances to reduce the number of tests on animals. Packaging of our products is environmentally friendly and materials degradable.
Correct Disposal of this Product
Information about WEEE Directive
Of major importance is the compliancy with the Waste Electrical and Electronic Equipment Directive (WEEE) as well. The scope of this Directive is the reuse, recycling, and disposal of electrical equipment during complete lifecycle and after their end of life.
The product and its electronic accessories should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Compliancy
Simplified EU Declaration of Conformity
Hereby, Etrel d.o.o. declares that the radio equipment type INCH is in compliance with Radio Equipment Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address:
https://etrel.com/charging-solutions/inch-home/ or
https://etrel.com/charging-solutions/inch-pro/
Select "Access documentation" and then "Certificates".
Tested Compliancy with Standards
Etrel INCH charging station was tested at accredited third-party laboratory SIQ - Slovenian Institute of Quality and Metrology. Performed tests cover all the requirements of RED, LVD and EMC directives of the European Union, according to the specifications of the following standards:
IEC 61851-1:2017 (EN IEC 61851-1:2019)
IEC 61851-21-2:2018
ETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V2.2.1
ETSI EN 301 489-52 V1.1.0
ETSI EN 301 489-3 V2.1.1
EN 60529:1991 + A1:2000 + A2:2013
EN 62262:2002
Safety Risk Analysis
All our charging stations are tested and proved compliant with EN 61851 Part 1, Part 21-2 and requirements of harmonized standards to fulfil LVD and EMC directive. These tests and judgement of compliancy was performed by external accredited organization, SIQ - Slovenian Institute of Quality and Metrology, Mašera - Spasićeva ulica 10, 1000 Ljubljana, Slovenia, www.siq.si.
Design Considerations
Special care has been put into selection of components and materials and their compliance to requirements set in standards, technical directives, and rules of good practice.
The internal wiring was carefully designed, and the propriety of whole assembly thoroughly evaluated. Basic design considerations include voltage, insulating materials, time under voltage stress and degree of pollution at the location.
Creepage distances, clearance between circuits and spacing to metal enclosures are important requirements for insulation coordination. Thus, calculation and measurement of clearance and creepage distances, in accordance with requirements, are one of the significant parts in design of our products. They are dimensioned to withstand the required impulse withstand voltage and to withstand the long-term continuous operation.
A charging station operates with an RCD device, which is designed to protect against the risks of electrocution and in addition offers protection against fire caused by earth faults. It is a sensitive safety device that switches off electricity automatically if there is a fault.
The ingress protection class of IP56 proves, that the enclosure of the charging station is protecting the internals against ingress of solid objects, permits only limited ingress of dust and is protected against water splashes from all directions. Impact protection, of at least IK10 states, that the charging station can withstand impacts, equivalent to 5 kg dropped from height of 40 cm. As required, tests for the IK class were performed before testing of IP class.
Licenses
At the same location as the complete EU Declaration of Conformity, in the folder "Licenses", manifest file with information about versions and licenses of integrated software can be found.
https://etrel.com/charging-solutions/inch-lite/
Select "Access documentation" and then "Licenses".
Transportation and Storage instructions
TRANSPORTATION
Please make sure that the charging station (or pallet of charging stations) is stable during the transport.
Transportation temperature range: -30 °C to +70 °C
STORAGE
The charging station is delivered in a cardboard box. We recommend that the charging station is kept in this packaging until the installation. Packaging must be removed before installation of the charging station.
Storage temperature range: -30 °C to +70 °C
STACKING
INCH Lite with cable:
5 boxes maximum stacking, symbol:
(Maximum of 4 boxes on top of the bottom box)
INCH Lite with socket:
7 boxes maximum stacking, symbol:
(Maximum of 6 boxes on top of the bottom box)
Packaging
Figure 2: Label on the packaging
PRODUCT DESCRIPTION
Basic Functionalities
Etrel INCH LITE is a smart charging station that can predict EV charging habits and help charge the car by the time it is needed, at the lowest possible cost.
To connect Etrel INCH LITE charging station, it either comes with the socket or cable. Depending on the type of charging station.
Status light Socket Maintenance doors Charging cable | |
Figure 3: Etrel INCH LITE with socket | Figure 4: Etrel INCH LITE with cable |
Figure 5: Dimensions of the charging station
Optional and Extra Equipment
Content and Accessories
Charging station (with Type 2 cable or Type 2 socket),
Wall mounting bracket,
9 × wall plugs for securing the mounting bracket using screws to the wall,
9 × screws to mount the bracket to the wall,
Screws dimensions: 4.5 x 40 and 4.5 x 60 [mm],
Cable gland rubber seal for smaller cable dimensions
*9 × wall spacers
*2 × keys to open charging station service doors,
*Hex key to open charging station maintenance doors,
Hex key dimensions: 2.5
*Load Guard device,
*Magnetic cable holder (different version for longer cables > 3 m).
*Optional depending on the purchased model.
Circuit Diagram
INSTALLATION PROCEDURE
OPERATION AND CHARGING PROCEDURE
First Power up
Before starting the station, it is absolutely necessary to read this manual and the technical specification of the device.
When the charging station is power up for the first time it can take several minutes for station to get ready to start using it to charge EV. Charging station is powered up automatically when it is connected to the electricity. In the table below, all possible events that can occur at the power up of the station are listed with the procedure what to do in case something is wrong.
STATUS LIGHT | NORMAL OPERATION | PROBLEM | SOLUTION |
Fast blinking green light | Charging station’s backup batteries are charging. At the first power, up it can take up to 10 min. If backup battery is full green light will blink slowly. | If the light is blinking fast more than 10 min there might be a problem with the backup battery. | Inform the support about the status of the charging station. |
Slowly blinking green light | Heating system is trying to heat the electronics before it is turned ON. | If the green light is blinking slowly for more than 10 minutes, there might be a problem with the hardware. | Support should be called. |
Steady glowing green light | Charging station is ready to be used. | / | / |
No lights | / | If charging station is not responding after it is powered up, something might be wrong with connection. | Check the protection elements if either RCD or overcurrent protection has been tripped. Activate the protection. If nothing helps call the support or installer. |
Green light is blinking | Charging station is ready to be used.
| Charging station is unresponsive. | Try resetting the charging station. If the problem repeats there might be a problem with the software. Support should be called.
|
First Charging Session
Check Whether the Charging Station is Working Properly and Setting of Maximal Charging Current
When the charging station has either overcurrent or RCD protection installed, check whether the protection element is in ON position.
Connect charging station to the power supply in the electrical cabinet. Installation feeder should be turned on.
The default value is 16 A and it can be set in range of 6 A to 32 A. Information of the current value is obtained with short press on the key. Number of short beeps represents information of set maximal charging current (number of beeps x 2 A).
Settings can be accessed with key press for more than 5 s. After that, a long beep is a notification that the settings can be changed. Each short press on the key increments the maximal charging current by 2 A, from minimal value of 6 A. E.g., to set 24 A, the key should be pressed 9 times.
To save the settings, press the key for more than 5 s. Long beep is a confirmation that settings were saved, two short beeps are a warning that settings were not saved.
Regular MAINTENANCE
Etrel charging station does not require any periodic maintenance. However, it is recommended to perform a visual check and test of the protection elements once per year.
Detailed descriptions of security checks and their intervals are included in the service manual.
Reset and Test the Protection Elements
Overcurrent Protection
Check the overcurrent protection (if installed) once a year for any visible damages on the surface. If the overcurrent protection is tripped and the switches cannot return to the active position something is wrong with the protection and needs to be changed by maintenance crew.
Surge and Overvoltage Protection
Check the surge and overvoltage protection (if installed) once a year for any visible damages on the surface. If the surge and overvoltage protection is tripped it needs to be changed by maintenance crew.
RCD
The regulations require that residual current protective device (RCD) is tested regularly, and an audit log should also be kept. The test button on the RCD unit allows user to verify the correct operation of the device by passing a small current through the RCD unit. This simulates a fault by creating an imbalance in the sense coil. If the RCD does not trip when this button is pressed, then the device must be replaced by licensed electrician. The device must be changed also when the RCD was tripped but the switch cannot be moved back into active position. RCD testing must be completed every three months and documented.
Figure 6: RCD test button
TROUBLESHOOTING
Errors dangerous to device users:
Dangerous voltage present on enclosure or device under fire. In this case the device should be turned off immediately. Switch off device power supply of device in the distribution board from where device is supplied and not on device itself. Do not touch device. If vehicle is connected at that moment, disconnect plug from the vehicle and not from the charging station, but only after the power supply was switched off. In the case of fire use fire extinguisher appropriate for electrical fire.
Faults occurred because of external conditions:
Undervoltage, overvoltage, short and long power supply outages or wrong vehicle behaviour. In these cases, no action is needed to re-establish normal operating conditions. Once fault is gone, normal operation conditions will be established automatically. If temporary fault was caused by vehicle, user will have to reinitiate charging session.
Device hardware failure preventing normal operation:
Example: Broken socket, electronics failure. If after restart device does not start normally, contact supplier support.
Charging station software failure:
Check that latest version of firmware is running on the charging station. If the latest version is installed and problem persist, then check if problem is caused by the charged vehicle. To check this, the charging could be tried on another charging station. If problem is not in the vehicle send diagnostic logs to the supplier.
Access to the Maintenance Area
Etrel INCH LITE charging station provides quick access to the side maintenance area to execute basic troubleshooting and to reset the charging station in case there are some problems.
Side maintenance area is protected by the side maintenance doors. Depending on the type of Etrel INCH LITE charging station, two different doors are available. One with the regular key lock and one with hex screw (2.5 mm). To access the area, either key or a hex screwdriver is needed.
Figure 7: Doors with keylock Figure 8: Doors with hex screw
There is a sticker on the inside of maintenance doors, with technical information including basic charging station information, model type and serial number. When support is contacted it is important that the charging station model type is known so the support can quickly help solve the issue.
Reseting the Charging Station
Charging station can be reset by opening the side maintenance doors and pressing the button inside the maintenance opening.
After holding the button for 4 s, the charging station will respond with the beep after which the options on the screen to check the IP address of the station or to reset the station will be presented. Basic reset and factory reset, which will restore charging station’s factory settings (username, password, default IP and other settings) can be made.
Figure 9: Reset button inside the maintenance opening
Warning! Before installing, wiring, handling or accessing the charging station in any way, make sure to read, understand and follow the Safety Guidelines.
Any graphic material provided in this documentation library is subject to variation and may not reflect the most recent updates or changes due to ongoing development and the implementation of new features.
Owing to periodic improvements of our products, the supplied products can differ in some details from the information stated in this documentation library. The information is subject to alteration without notice.
The English version of this documentation is the official and authoritative source of information. We make every effort to ensure that translations are accurate and clear; however, we do not accept responsibility for any errors, omissions, or misinterpretations in translated versions. In case of discrepancies, the English version will take precedence.