Table of Contents
Table of Contents |
---|
GENERAL CONFIGURATION information
Etrel Inch charging station is configured using the web interface which can be accessed through the charging station IP. Additional settings can be adjusted using OCPP messages using the backend system.
Configurations cannot be made using the touch screen LCD as it is only used to show information what is happening with the charging station and offers to user basic controls of the charging session.
Sign In
Web interface can be accessed by connecting to the charging station IP. For the connection, the username (email) and password are needed.
...
Last session status will be shown on the right side of the screen. If anything went wrong during the session, additional information can be acquired in the Diagnostics menu, accessed using the main menu (icon with three lines in the top left corner).
Change the Language
The language of the web interface can be changed to one of the languages supported by the web interface, by pressing the main menu icon and selecting the desired language.
...
Figure 4: Changing the language
Charging Station configuration
User Rights
Charging station configuration possibilities differ depending on the Role of the user. Three roles exist: View, Operate and Admin.
...
Figure 5: Full range of configuration possibilities
Change Charging Station Mode Settings
These options can be accessed only by users with Admin rights. Charger mode settings can be configured by pressing the “Charger configuration” and then “Charger mode” in the “Configuration” menu. The option is to choose between Home charger used by single user, Private/Public charger used by multiple users and Custom mode.
...
Figure 6: Setting the charger mode
Web Interface Access
By pressing “Charger configuration” and then “Web interface access” in “Configuration” menu it is possible to give certain users roles which will give them different access to the charging station’s settings and options.
...
“Anonymous view access enabled” option allows unsigned users to see the dashboard and check charging session.
Change Supported Languages
Selection of languages that will be available on the charging station LCD screen can be changed with selection of “Charger configuration” and “Time and Regional settings” in “Configuration” menu.
...
Figure 12: Adding custom translations
Time and Regional Settings
Time settings of the charging station are set with selection of “Charger configuration” and then “Time and Regional settings”. The charging station time can be set. It can also be synchronized with the computer time by pressing the “Synchronize time” button. The time zone of the location where the charging station is located can also be selected.
...
Figure 13: Time settings
Currency Settings
In the “Time and Regional settings” in “Charger configuration” it is possible to choose the currency in which the energy prices will be displayed.
...
Figure 14: Currency settings
Behaviour Before and at the end of Charging
These options allow admin to enable certain functionalities before and at the end of charging. The following functionalities can be enabled:
...
Figure 15: Setting behaviour before and at the end of charging
Change Screen Saver Parameters
How many seconds of inactivity are needed for charging station to go into screensaver mode can also be set by going into “Charger configuration” and then select “GUI settings” in “Configuration” menu.
...
Figure 16: Screensaver settings
Change Wake up Logo
Wake up logo can be changed in the “Charger configuration” and then “GUI settings” in “Configuration” menu. By default, Etrel logo will be shown. By pressing the “Change wake up logo”, custom logo can be selected.
...
Figure 17: Selection of custom wake up logo
Figure 18: Uploading the image of custom wake up logo
Change Display Information During Charging
The display settings can be changed in “Configuration” menu by going into “Charger configuration” and then “GUI settings”. Various options what can be displayed are available. Multiple options can be selected, and the screen will switch every X seconds, based on the “Change screen settings” setting.
...
“Super” option is a special option and displays all the information about range, charging mode and departure time on one screen.
EVSE’s Configuration
Charging station EVSE’s configuration can be changed by going to “Configuration” in the main menu and then to “Charger configuration” and then to “EVSE’s configuration”. Various parameters of each EVSE can be changed:
...
Figure 20: EVSE’s configuration
Limit Maximum Charging Current
The charging station charging power can be limited by limiting the max current value. With the limitation the possibility of overloading the grid can be prevented. This option is available under the “Charger configuration” in the “EVSE’s configuration” option under the “Configuration” menu.
User
User settings have different options depending on the charger mode chosen.
...
Local users
Charging authorization
Home Charger Used by Single User Mode
“My profile” option is used to write the first and last name of the user that will be using this charging station. The electric vehicle that the user is using can be added in the “My vehicle” options.
...
Figure 22: Adding the electric vehicle information
Private/Public Charger Used by Multiple Users
The option to add multiple users is available only in the Private/Public charger used by multiple users. “Local users” option opens by pressing the “Add new” button and allows the creation of new users. First and last name of the users need to be inserted.
...
When adding new identification, already swiped RFID cards will be available, or the system will ask you to swipe the card and then it will add it to the system.
Figure 25: Adding new identification
...
Figure 28: Selection of charging authorization type
Choose Supported Identifications
Identifications that are supported by the charging station are first dependent on the type of charging station and on which authorization modules are installed inside the charging station.
...
Figure 29: Selection of supported identification types
Set Central System Behaviour
In the “User”, “Charging authorization” option menu it is possible to set Central system behaviour. Different modes of behaviour are supported. Options are:
...
Figure 30: Settings of central system behaviour
Setting Advertisements on the LCD Screen
LCD screen advertisement can be set in the “Configuration”, “Advertising” option. It is possible to set on which days and at which hour particular picture/advertisement will be shown.
...
To enable the advertisements on the charging station LCD screen, this option needs to be selected in the “Configuration”, “Charger configuration”, “GUI settings”. The advertisement duration in seconds can also be set.
Connect to the Communication network
Connectivity section of “Configuration” menu is especially important during the installation of charging station or if communication problems are occurring. Connectivity menu allows setting of parameters of connectivity that are available in your charging station. Depending on the charging station model, different connectivity options can be available.
...
Ethernet
Wi-Fi
GSM
Central system
Ethernet Connectivity
When setting up connection using the Ethernet, this needs to be specified in the Ethernet connectivity in the Connectivity section of the “Configuration” menu.
...
Figure 33: Ethernet connectivity settings
Wi-Fi Connectivity
Connection using the Wi-Fi module is set in the Connectivity section of “Configuration” menu and in Wi-Fi connectivity.
...
Figure 34: Scanning of Wi-Fi networks
Figure 35: Example of list with found networks
...
Same process of identifying the available Wi-Fi networks and connecting to one, can be started by pressing the Wi-Fi icon in the top right corner.
...
Figure 38: Wi-Fi icon
GSM Connectivity
Setting up connection using the GSM module is set up in the GSM connectivity in the Connectivity section of “Configuration” menu. There it is possible to change multiple settings to properly set up GSM communication.
...
By pressing the “Configuration” button, “GSM connectivity”, settings will open.
Central System Connectivity
To connect charging station to the central system, various settings in the “Central system connectivity” module need to be set. The communication with central system can be enabled by ticking the enable button.
...
Figure 43: Configuration icon
Figure 44: Status of central system connection
Power management
Power management settings allow operators to set various aspects of power management functionalities and cluster settings. Settings are available for Power management configuration, to turn the power management on or off and to define if charging station is Master or Slave device. Other settings are Building power limits, Power cluster configuration, Energy prices and Frequency control.
...
Figure 45: Power management settings
Power Limits at the Location
Building power limits settings allows setting of current limitation for the complete consumption at the location (e.g. included consumption of the consumers of electricity of the household and the consumption of charging station). Charging station current limits are calculated for each phase separately to not exceed the household grid limits or limits of the fuses.
...
Additional security limits can also be set to reduce the maximal current of each phase in the event when the communication with the Load Guard is interrupted.
Load Guard Settings
In the same options menu, it is possible to set the Load Guard device:
IP address
Serial no.
Load Guard Configuration
To configure the Load Guard, software developed by Etrel is used to do this. Download link can be found on the Etrel internet site (https://etrelchargingsolutions.atlassian.net/wiki/spaces/Home/pages/258867203/Configuration+software).
...
Also, the Load Guard communication settings can be changed from dynamic IP to static IP address.
Power Cluster Configuration
Power cluster configuration options in the web interface allow you to define which charging stations are parts of the cluster, set IP of the primary and secondary master and set maximal current output if the communication with the cluster master is interrupted.
...
Figure 51: Setting max. cluster currents
Cluster Primary Master
To configure primary master, the option ”Connect this charger to the cluster” needs to be enabled. Write in primary master address or acquire it simply by pressing the “Running on this charger”.
...
Last option is “Max cluster currents”, which will define limit for all the phases for the whole cluster.
Secondary Master
Secondary master is not mandatory, but it can provide redundancy in the case when primary master loses communication or if there is a fault. Setting up secondary master is almost the same as for the primary master.
Enabling the “Connect this charger to the cluster” and ticking “Enable also secondary master”. Secondary master IP can be acquired by pressing the “Running on this charger”. For the primary master, the primary master local IP needs to be inserted. That address can also be obtained with the button.
Charging Station Part of the Cluster
For all the charging station that are part of the cluster and are not primary or secondary master first the “Connect this charger to the cluster” option needs to be enabled and the address of primary and secondary master inserted (if they are used). Local IP address of the master can be obtained by pressing the “Running on this charger” button.
...
When configuring charging stations that are part of the cluster, make sure that primary master is live, up and running.
Checking Cluster Configuration
Cluster configuration can be checked with clicking the icon in the top right corner.
...
Figure 53: Charging stations of the cluster
Electrical Energy Prices
In the Energy prices menu, it is possible to define multiple electricity tariffs, which will allow electric vehicle charging using the economic power management. This means that the charging station will be able to charge using the price signal and consequently reduce the cost of charging. When creating the tariff, it is also possible to define prices and times when the tariff is valid.
...
Figure 54: Energy prices settings
Frequency Control
Etrel Inch charging station is capable helping with the frequency regulation. In the Frequency control menu, the frequency parameters can be set. In case of under frequency the charging power of the charger is lowered, by the value needed and is kept at that value until the frequency is restored to the normal value.
...
Figure 55: Frequency power management settings
Reporting
Reporting section of the web interface can be accessed using the main menu (icon with three lines in the top left corner).
...
Sessions.
Authorizations and
Events,
Sessions
In the session reports it is possible to check all the sessions that took place on the particular charging station during the chosen time frame. It is possible to filter the session based on the identification source, identification type, identification code, session stop reason and based on the selected user. If needed all the data can be exported by pressing the “Export to CSV” button.
...
Figure 57: Sessions report
Authorizations
Authorization reports show all the authorizations that took place on the charging station. Search functionality can be used to search for a particular authorization.
...
Figure 58: Authorizations report
Events
Events report allows to see all the events that happened on the charging station in the chosen time frame. Application of various filters to find specific events is possible. Searches can base on the Priority, Category and Event type. All the data can be exported to CSV file.
...
Figure 59: Overview of charging station events
Diagnostics
If experiencing problems, the “Diagnostics” menu can be used to identify them. There it is possible to download logs, which can be sent to the operator to check what is wrong with charging station. Also, basic information about the charging station can be obtained there:
...