We discovered that some cars made on same EV platform from Stellantis doesn’t want to charge with our three phase INCH chargers with MID meters and are connected to electrical grid only with single phase.

Issue is with Stellantis group on-board charger for their EV lineup. All other cars should charge normally and without any issue.

Affected INCH chargers

INCH Models are models G-PC1<*>B<*><*><*>0

Affected cars

The affected models of cars are:

  • Peugeot e-208

  • Peugeot e-2008

  • Peugeot e-Rifter

  • Citroen e-C4

  • Opel Corsa-e

  • Opel Mokka-e

Basically every Stellantis car that have same on-board chargers as the cars on the list above.

After you plug in the car, there will be message or error on the screen, Charging paused by EV or Critical Error.

You can also check in the Event list, you will get message Charging paused by EV.

In those scenarios we suggest that you either connect charging station with all three phases or swap charging station with one without MID.