Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

We discovered that some cars made on same EV platform from Stellantis doesn’t want to charge with our three phase INCH chargers with MID meters and are connected to electrical grid only with single phase, that is the issue with Stellantis group on-board charger. All other cars should charge normally and without any issue.

INCH

INCH Models are models G-PC1<*>B<*><*><*>0

Cars

The affected list of cars is:

  • Peugeot e-208

  • Peugeot e-2008

  • Peugeot e-Rifter

  • Citroen e-C4

  • Opel Corsa-e

  • Opel Mokka-e

Basically every Stellantis car that have same on-board chargers as the cars on the list above.

After you plug in the car, there will be message or error on the screen, Charging paused by EV or Critical Error.

You can also check in the Event list, you will get message Charging paused by EV.

In those scenarios we suggest that you either connect charging station with all three phases or swap charging station with one without MID.

  • No labels