VesnaV - 30-Oct-2023: Instead of the main product properties, the Tech Datasheet will be inserted (when the review will be done and the final version will be available).
VesnaV - ToDo: check if all properties listed below are integrated in the Datasheet. If not, list the missing ones separately. Also check corrections in the reviewed docx where comments and corrections are available.
...
Smart charging station for domestic and residential charging environments
...
Maximum charging power:
One-phase installation: 7.4 kW (1 × 32 A)
Three-phase installation: 22 kW (3 × 32 A)
...
Charging outlet type:
Type 2 socket
Type 2 tethered charging cable
...
Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C). | ||
Electrical characteristics | ||
Single-phase device | Input | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW |
Output | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW | |
Three-phase device | Input | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW |
Output | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW | |
Types of system earthing | TN, TT | |
Rated impulse withstand voltage (Uimp) | 2500 V – OVC II (4000 V and OVC III is achieved with installed SPD) | |
Rated insulation voltage (Ui) | 230/400 V | |
Rated current of each circuit (Inc) | 32 A | |
Rated peak withstand current (Ipk) | 4500 A | |
Rated conditional short-circuit current of assembly (Icc) | 3000 A | |
Rated diversity factor (RDF) |
| |
Device power consumption | 10–15 W (highest measured value of full configuration) |
...
Environmental characteristics | ||
Ingress protection | IP56 | |
Impact protection |
...
Ingress protection: IP56 protection against dust and liquid penetration (by IEC 60529)
...
Electrical protection:
DC fault current sensors 6 mA (default)
PEN protection (UK edition)
Other protection installed externally upstream
...
Communication technologies allow BEMS, cloud integration and ensure communication stability.
Connectivity
Wi-Fi – for WLAN connection
Bluetooth & Wi-Fi – for Smartphone mobile app connection
Sub-1 GHz – for wireless connection with Load Guard (when used)
EV communication:
IEC 61851
ISO 15118 – supported by design, not available at launch
Local communication protocols, Smart building integration: MQTT, Modbus RTU, OCPP
Cloud connection: OCPP (1.6 starting version)
RS-485 terminals for connection with an external meter
...
Energy meter:
embedded class 2 energy meter
can be connected with a MID compliant meter
...
Modes of charging:
Fast
Interactive
...
User identification: Smartphone app, RFID
...
User interface: LED and sound signals, press button, smartphone app
...
Material: Polycarbonate reinforced with glass fibers, TPE gasket
...
Colour: Light grey (RAL 7001)
...
Modularity – the charging station consists of three modules – enables simple and fast product delivery and installation:
Module 1 – Dock (Wallmount)
Module 2 – Output socket without shutter / Output socket with shutter / Output cable
Module 3 – Main unit
...
The charging station offers versatile connectivity options to suit various energy management systems:
integration with Local Energy Management System (LEMS)
integration with Cloud Energy Management System (CEMS)
standalone operation with Dynamic Load Management (DLM)
...
Setting up of the charging station, as well as FW upgrade, can be done locally or remotely, in compliance with the predefined security levels.
Charging station customization:
...
Encloser branding with laser printing
...
App branding
...
Access levels (when the top cover of the main unit is removed)
...
IK10 | ||
Protection class | Class I equipment | |
Pollution degree | Pollution Degree 3 | |
Electromagnetic compatibility (EMC) |
| |
Frequency bands and radio power | ||
Wi-Fi | Frequency band: 2.4 GHz Transmitting power: up to 20.5 dBm (adjustable) | |
Sub-GHz | Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz Transmitting power: 14 dBm | |
RFID module | Frequency band: 13.56 MHz (HF) Transmitting power: up to 8 dBm (ISO 14443 and ISO 15693) | |
Other classification and characteristics | ||
AEVCS | Assembly intended for charging stations for electric vehicles | |
Installation location | Indoor and Outdoor | |
Mounting method | Stationary equipment, Wall-mounted assembly | |
Location accessibility | Location with restricted access or non-restricted access | |
Mechanical resistance | Medium/High | |
Installation | Must be performed by qualified personnel | |
Operation | Allowed to ordinary persons | |
Electrical installation protection | ||
Dimensions | ||
Dimensions of assembled charging station (in mm) | H2 - to the bottom of the cable gland with a spiral | |
Main unit + Dock | 257 × 273 × 115 (W × H1 × D) | |
Main unit + Output socket + Dock | 257 × 401 × 115 (W × H2 × D) | |
Main unit + Output socket shutter + Dock | 257 × 413 × 120 (W × H2 × D) | |
Main unit + Output Cable + Dock | 257 × 387 × 115 (W × H2 × D) | |
Mass | ||
Mass (assembled charging station) | 3.4 kg to 7 kg | |
Temperature | ||
Operational | -25 °C to +85 °C | |
Ambiental | -25 °C to +50 °C | |
Storage | -30 °C to +85 °C |