Single-phase or three-phase EV charging station for

...

Maximum charging power:

  • One-phase installation: 7.4 kW (1 × 32 A)

  • Three-phase installation: 22 kW (3 × 32 A)

...

Charging outlet type:

  • Type 2 socket

  • Type 2 tethered charging cable

...

any electric vehicle with a Type 2 charging connector (identifier C).

Electrical characteristics

Single-phase device

Input

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Output

230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW

Three-phase device

Input

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Output

230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW

Types of system earthing

TN, TT

Rated impulse withstand voltage (Uimp)

2500 V – OVC II (4000 V and OVC III is achieved with installed SPD)

Rated insulation voltage (Ui)

230/400 V

Rated current of each circuit (Inc)

32 A

Rated peak withstand current (Ipk)

4500 A

Rated conditional short-circuit current of assembly (Icc)

3000 A

Rated diversity factor (RDF)

  • 1 (without load control),

  • 0 to 1 (with proper setup of load control)

Device power consumption

10–15 W (highest measured value of full configuration)

...

Environmental characteristics

Ingress protection

IP56

Impact protection

...

Ingress protection: IP56 protection against dust and liquid penetration (by IEC 60529)

...

Electrical protection:

  • DC fault current sensors 6 mA (default)

  • PEN protection (UK edition)

  • Other protection installed externally upstream

...

Communication technologies allow BEMS, cloud integration and ensure communication stability.

  • Connectivity

    • Wi-Fi – for WLAN connection

    • Bluetooth & Wi-Fi – for Smartphone mobile app connection

    • Sub-1 GHz – for wireless connection with Load Guard (when used)

  • EV communication:

    • IEC 61851

    • ISO 15118 – supported by design, not available at launch

  • Local communication protocols, Smart building integration: MQTT, Modbus RTU, OCPP

  • Cloud connection: OCPP (1.6 starting version)

  • RS-485 terminals for connection with an external meter

...

Energy meter:

  • embedded class 2 energy meter

  • can be connected with a MID compliant meter

...

Modes of charging:

  • Fast

  • Interactive

...

User identification: Smartphone app, RFID

...

User interface: LED and sound signals, press button, smartphone app

...

Material: Polycarbonate reinforced with glass fibers, TPE gasket

...

Colour: Light grey (RAL 7001)

...

Modularity – the charging station consists of three modules – enables simple and fast product delivery and installation:

  • Module 1 – Dock (Wallmount)

  • Module 2 – Output socket without shutter / Output socket with shutter / Output cable

  • Module 3 - Main unit

...

The charging station offers versatile connectivity options to suit various energy management systems:

  • integration with Local Energy Management System (LEMS)

  • integration with Cloud Energy Management System (CEMS)

  • standalone operation with Dynamic Load Management (DLM)

...

Setting up of the charging station, as well as FW upgrade, can be done locally or remotely, in compliance with the predefined security levels.

Charging station customization:

...

Encloser branding with laser printing

...

App branding

...

Access levels (when the top cover of the main unit is removed)

...

IK10

Protection class

Class I equipment

Pollution degree

Pollution Degree 3

Electromagnetic compatibility (EMC)

  • EMC emissions: Class B (residential)

  • EMC immunity: Class A (other than residential)

Frequency bands and radio power

Wi-Fi

Frequency band: 2.4 GHz 

Transmitting power: up to 20.5 dBm (adjustable)

Sub-GHz 

Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz

Transmitting power: 14 dBm

RFID module

Frequency band: 13.56 MHz (HF)

Transmitting power: up to 8 dBm

(ISO 14443 and ISO 15693)

Other classification and characteristics

AEVCS

Assembly intended for charging stations for electric vehicles

Installation location

Indoor and Outdoor

Mounting method

Stationary equipment, Wall-mounted assembly

Location accessibility

Location with restricted access or non-restricted access

Mechanical resistance

Medium/High

Installation

Must be performed by qualified personnel

Operation

Allowed to ordinary persons

Electrical installation protection

  • Short-circuit protective device(s):
    Appropriate MCB or fuse must be part of electrical installation, installed upstream of the charging station.

  • Protection against electric shock:
    Appropriate RCD must be part of electrical installation, installed upstream of the charging station. 

Dimensions

Dimensions of assembled charging station (in mm)

image-20240229-135419.pngImage Added

H2 - to the bottom of the cable gland with a spiral

Main unit + Dock

257 × 273 × 115 (W × H1 × D)

Main unit + Output socket + Dock

257 × 401 × 115 (W × H2 × D)

Main unit + Output socket shutter + Dock

257 × 413 × 120 (W × H2 × D)

Main unit + Output Cable + Dock

257 × 387 × 115 (W × H2 × D)

Mass

Mass (assembled charging station)

3.4 kg to 7 kg
(depending on the configuration and cable length)

Temperature

Operational

-25 °C to +85 °C

Ambiental

-25 °C to +50 °C

Storage