The charging station supports Dynamic Load Management (DLM). Using DLM, the charging system safely balances energy consumption between your electric vehicle, charging station and other devices in your internal electricity grid. The functionality enables adjusting the current limit based on real-time measurements and signals that enhances the functionality of the EV charging station by providing intelligent control over charging power.
...
For DLM to function in a standalone INCH Core charging station, an external metering device must be used:
INCH Core Load Guard (supports wireless connection), or
an external electricity meter* supporting Modbus RTU communication via RS-485 wired connection, or
combination of both.
...
the INCH Core Load Guard and an external electricity meter* supporting
Modbus RTU communication via RS-485,
P1 communication via the P1 port, or
TIC communication via the TIC port.
* Refer to the list of electricity meters supported by the INCH Core charging station.
The INCH Core Load Guard supported by INCH Core charging station is not available yet and will be available soon.
...
DLM configuration can be set via the INCH Core app or a central system (e.g., EMSP).
1. Enable DLM via the Dynamic load management page of the INCH Core app, or a central system if applicable.
...
To configure Load Guard for DLM to function with the charging station, refer to the INCH Core Load Guard guidelines.
The guidelines will be available when the INCH Core Load Guard will be launched.
External electricity meter
...
connected to the charging station via the RS-485 connection as required in the connection diagram /wiki/spaces/EKC/pages/3702784128 and the meter documentation,
configured in such a way that the charging station can be able to communicate with it.
...
Anchor | ||||
---|---|---|---|---|
|
Address
Baud rate
Data bits
Parity
Stop bit
When you select your meter type from the dropdown list in the INCH Core app, the listed parameters can be pre-configured. However, the actual values of these parameters may differ from the default values. It's important to verify and set the correct actual values accordingly.