Single-phase or three-phase EV charging station for |
...
any electric vehicle with a Type 2 charging connector (identifier C). | ||
Electrical characteristics | ||
Single-phase device | Input | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW |
Output | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW | |
Three-phase device | Input | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax |
...
; 22 kW |
Output |
...
230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax |
...
Maximum charging power:
One-phase installation: 7.4 kW (1 × 32 A)
Three-phase installation: 22 kW (3 × 32 A)
...
Charging outlet type:
Type 2 socket
Type 2 tethered charging cable
...
; 22 kW | ||
Types of system earthing | TN, TT | |
Rated impulse withstand voltage (Uimp) | 2500 V – OVC II (4000 V and OVC III is achieved with installed SPD) | |
Rated insulation voltage (Ui) | 230/400 V | |
Rated current of each circuit (Inc) | 32 A | |
Rated peak withstand current (Ipk) | 4500 A | |
Rated conditional short-circuit current of assembly (Icc) | 3000 A | |
Rated diversity factor (RDF) |
| |
Device power consumption | 10–15 W (highest measured value of full configuration) |
...
Modes of charging:
Fast
Interactive
...
Level of protection:
Impact protection: IK10
Ingress protection class: IP56
...
Electrical protection:
DC fault current sensors 6 mA (default)
PEN protection (UK edition)
Other protection installed externally upstream
...
Temperature:
Operational temperature: -25 °C to +85 °C
Ambiental temperature: -25 °C to +50 °C
...
Environmental characteristics | ||
Ingress protection | IP56 | |
Impact protection | IK10 | |
Protection class | Class I equipment | |
Pollution degree | Pollution Degree 3 | |
Electromagnetic compatibility (EMC) |
| |
Frequency bands and radio power | ||
Wi-Fi | Frequency band: 2.4 |
...
GHz Transmitting power: |
...
up to 20.5 dBm (adjustable) |
...
...
Sub- |
...
GHz | Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 |
...
MHz Transmitting power: 14 |
...
dBm | ||
RFID module | Frequency band: 13.56 MHz (HF) Transmitting power: up to 8 dBm (ISO 14443 and ISO 15693) | |
Other classification and characteristics | ||
AEVCS | Assembly intended for charging stations for electric vehicles | |
Installation location | Indoor and Outdoor | |
Mounting method | Stationary equipment, Wall-mounted assembly | |
Location accessibility | Location with restricted access or non-restricted access | |
Mechanical resistance | Medium/High | |
Installation | Must be performed by qualified personnel | |
Operation | Allowed to ordinary persons | |
Electrical installation protection | ||
Dimensions | ||
Dimensions of assembled charging station (in mm) | H2 - to the bottom of the cable gland with a spiral | |
Main unit + Dock | 257 × 273 × 115 (W × H1 × D) | |
Main unit + Output socket + Dock | 257 × 401 × 115 (W × H2 × D) | |
Main unit + Output socket shutter + Dock | 257 × 413 × 120 (W × H2 × D) | |
Main unit + Output Cable + Dock | 257 × 387 × 115 (W × H2 × D) | |
Mass | ||
Mass (assembled charging station) | 3.4 kg to 7 kg | |
Temperature | ||
Operational | -25 °C to +85 °C | |
Ambiental | -25 °C to +50 °C | |
Storage | -30 °C to +85 °C |