Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C). | ||
Electrical characteristics | ||
Single-phase device | Input | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW |
Output | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW | |
Three-phase device | Input | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW |
Output | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW | |
Types of system earthing | TN, TT | |
Rated impulse withstand voltage (Uimp) | 2500 V – OVC II (4000 V and OVC III is achieved with installed SPD) | |
Rated insulation voltage (Ui) | 230/400 V | |
Rated current of each circuit (Inc) | 32 A | |
Rated peak withstand current (Ipk) | 4500 A | |
Rated conditional short-circuit current of assembly (Icc) | 3000 A | |
Rated diversity factor (RDF) |
| |
Device power consumption | 10–15 W (highest measured value of full configuration) | |
Environmental characteristics | ||
Ingress protection |
...
IP56 | ||
Impact protection | IK10 | |
Protection class | Class |
...
I equipment |
...
Pollution degree | Pollution Degree 3 | |
Electromagnetic compatibility (EMC) |
| |
Frequency bands and radio power | ||
Wi-Fi | Frequency band: 2.4 |
...
Transmitting power: Up to 20.5 dBm (adjustable)
...
GHz |
Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz
Transmitting power: |
...
RFID module
Frequency band: 13.56 MHz (HF)
...
up |
...
(ISO 14443 and ISO 15693)
...
Other classification and characteristics
...
AEVCS
...
Assembly intended for charging stations for electric vehicles
...
Installation location
...
Indoor and Outdoor
...
Mounting method
...
Stationary equipment, Wall-mounted assembly
...
Location accessibility
...
Location with restricted access or non-restricted access
...
Mechanical resistance
...
Medium/High
...
Installation
...
Must be performed by qualified personnel
...
Operation
...
to |
...
Electrical installation protection
...
Short-circuit protective device(s):
Appropriate MCB or fuse must be part of electrical installation, installed upstream of the charging station.Protection against electric shock:
Appropriate RCD must be part of electrical installation, installed upstream of the charging station.
...
Dimensions
...
Dimensions of assembled charging station (in mm)
...
H2 - to the bottom of the cable gland with a spiral
...
Main unit + Dock
...
257 × 273 × 115 (W × H1 × D)
...
Main unit + Output socket + Dock
...
257 × 401 × 115 (W × H2 × D)
...
Main unit + Output socket shutter + Dock
...
257 × 413 × 120 (W × H2 × D)
...
Main unit + Output Cable + Dock
...
257 × 387 × 115 (W × H2 × D)
...
Mass
...
Mass (assembled charging station)
...
3.4 kg to 7 kg
(depending on the configuration and cable length)
...
Temperature
...
Operational
...
-25 °C to +85 °C
...
Ambiental
...
-25 °C to +50 °C
...
Storage
...
-30 °C to +85 °C
...
Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C).
...
Electrical characteristics
...
Single-phase device
...
Input
...
230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW
...
Output
...
230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW
...
Three-phase device
...
Input
...
230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW
...
Output
...
230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW
...
Types of system earthing
...
TN, TT
...
Rated impulse withstand voltage (Uimp)
...
2500 V – OVC II (4000 V and OVC III is achieved with installed SPD)
...
Rated insulation voltage (Ui)
...
230/400 V
...
Rated current of each circuit (Inc)
...
32 A
...
Rated peak withstand current (Ipk)
...
4500 A
...
Rated conditional short-circuit current of assembly (Icc)
...
3000 A
...
Rated diversity factor (RDF)
...
1 (without load control),
0 to 1 (with proper setup of load control)
...
Device power consumption
...
10–15 W (highest measured value of full configuration)
...
Environmental characteristics
...
Ingress protection
...
IP55
...
Impact protection
...
IK10
...
Protection class
...
Class II equipment – double insulation
...
Pollution degree
...
Pollution Degree 3
...
Electromagnetic compatibility (EMC)
...
EMC emissions: Class B (residential)
EMC immunity: Class A (other than residential)
...
Frequency bands and radio power
...
Wi-Fi
Frequency band: 2.4 GHz
...
20.5 dBm (adjustable) | ||
Sub-GHz | Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz Transmitting power: 14 dBm | |
RFID module | Frequency band: 13.56 MHz (HF) Transmitting power: up to 8 dBm (ISO 14443 and ISO 15693) | |
Other classification and characteristics | ||
AEVCS | Assembly intended for charging stations for electric vehicles | |
Installation location | Indoor and Outdoor | |
Mounting method | Stationary equipment, Wall-mounted assembly | |
Location accessibility | Location with restricted access or non-restricted access | |
Mechanical resistance | Medium/High | |
Installation | Must be performed by qualified personnel | |
Operation | Allowed to ordinary persons | |
Electrical installation protection | ||
Dimensions | ||
Dimensions of assembled charging station (in mm) |
...
H2 - to the bottom of the cable gland with a spiral | ||
Main unit + Dock | 257 × 273 × 115 (W × H1 × D) | |
Main unit + Output socket + Dock | 257 × 401 × 115 (W × H2 × D) | |
Main unit + Output socket shutter + Dock | 257 × 413 × 120 (W × H2 × D) | |
Main unit + Output Cable + Dock | 257 × 387 × 115 (W × H2 × D) | |
Mass | ||
Mass (assembled charging station) | 3.4 kg to 7 kg | |
Temperature | ||
Operational | -25 °C to +85 °C | |
Ambiental | -25 °C to +50 °C | |
Storage | -30 °C to +85 °C |