Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C).
Electrical characteristics
Single-phase device
Input
230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW
Output
230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW
Three-phase device
Input
230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW
Output
230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW
Types of system earthing
TN, TT
Rated impulse withstand voltage (Uimp)
2500 V – OVC II (4000 V and OVC III is achieved with installed SPD)
Rated insulation voltage (Ui)
230/400 V
Rated current of each circuit (Inc)
32 A
Rated peak withstand current (Ipk)
4500 A
Rated conditional short-circuit current of assembly (Icc)
3000 A
Rated diversity factor (RDF)
1 (without load control),
0 to 1 (with proper setup of load control)
Device power consumption
10–15 W (highest measured value of full configuration)
Environmental characteristics
Ingress protection
IP55
Impact protection
IK10
Protection class
Class II equipment – double insulation
Pollution degree
Pollution Degree 3
Electromagnetic compatibility (EMC)
EMC emissions: Class B (residential)
EMC immunity: Class A (other than residential)
Frequency bands and radio power
Wi-Fi
Frequency band: 2.4 GHz
Transmitting power: Up to 20.5 dBm (adjustable)
Sub-GHz
Frequency bands: 169 MHz, 410–510 MHz, 868 MHz, or 915 MHz
Transmitting power: 14 dBm
RFID module
Frequency band: 13.56 MHz (HF)
Transmitting power: up to 8 dBm
(ISO 14443 and ISO 15693)
Other classification and characteristics
AEVCS
Assembly intended for charging stations for electric vehicles
Installation location
Indoor and Outdoor
Mounting method
Stationary equipment, Wall-mounted assembly
Location accessibility
Location with restricted access or non-restricted access
Mechanical resistance
Medium/High
Installation
Must be performed by qualified personnel
Operation
Allowed to ordinary persons
Electrical installation protection
Short-circuit protective device(s):
Appropriate MCB or fuse must be part of electrical installation, installed upstream of the charging station.Protection against electric shock:
Appropriate RCD must be part of electrical installation, installed upstream of the charging station.
Dimensions
Dimensions of assembled charging station (in mm)
H2 - to the bottom of the cable gland with a spiral
Main unit + Dock
257 × 273 × 115 (W × H1 × D)
Main unit + Output socket + Dock
257 × 401 × 115 (W × H2 × D)
Main unit + Output socket shutter + Dock
257 × 413 × 120 (W × H2 × D)
Main unit + Output Cable + Dock
257 × 387 × 115 (W × H2 × D)
Mass
Mass (assembled charging station)
3.4 kg to 7 kg
(depending on the configuration and cable length)
Temperature
Operational
-25 °C to +85 °C
Ambiental
-25 °C to +50 °C
Storage
-30 °C to +85 °C