Single-phase or three-phase EV charging station for any electric vehicle with a Type 2 charging connector (identifier C). | ||||
Electrical characteristics | ||||
Single-phase device | Input | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW | ||
Output | 230 V~; 1W+N+PE; 50/60 Hz; 32 Amax; 7.4 kW | |||
Three-phase device | Input | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW | ||
Output | 230/400 V~; 3W+N+PE; 50/60 Hz; 32 Amax; 22 kW | |||
Types of system earthing | TN, TT | |||
Rated impulse withstand voltage (Uimp) | 2500 V – OVC II (4000 V and OVC III is achieved with installed SPD) | |||
Rated insulation voltage (Ui) | 230/400 V | |||
Rated current of each circuit (Inc) | 32 A | |||
Rated peak withstand current (Ipk) | 4500 A | |||
Rated conditional short-circuit current of assembly (Icc) | 3000 A | |||
Rated diversity factor (RDF) | · 1 (without load control), · 0 to 1 (with proper setup of load control) | |||
Device power consumption | 10–15 W (highest measured value of full configuration) | |||
Environmental characteristics | ||||
Ingress protection | IP55 | |||
Impact protection | IK10 | |||
Protection class | Class II equipment – double insulation | |||
Pollution degree | Pollution Degree 3 | |||
Electromagnetic compatibility (EMC) | · EMC emissions: Class B (residential) · EMC immunity: Class A (other than residential) | |||
Frequency bands and radio power | ||||
Wi-Fi | Frequency band: 2.4 GHz Transmitting power: Up to 20.5 dBm (adjustable) | |||
Sub-GHz | Frequency bands: Transmitting power: 14 dBm | |||
RFID module | Frequency band: 13.56 MHz (HF) Transmitting power: up to 8 dBm (ISO 14443 and ISO 15693) | |||
Other classification and characteristics | ||||
AEVCS | Assembly intended for charging stations for electric vehicles | |||
Installation location | Indoor and Outdoor | |||
Mounting method | Stationary equipment, Wall-mounted assembly | |||
Location accessibility | Location with restricted access or non-restricted access | |||
Mechanical resistance | Medium/High | |||
Installation | Must be performed by qualified personnel | |||
Operation | Allowed to ordinary persons | |||
Electrical installation protection | · Short-circuit protective device(s): · Protection against electric shock: | |||
Dimensions | ||||
Dimensions of assembled charging station (in mm) | NM: pic to be replaced with a better quality one||||
Main unit + Dock | 257 × 273 × 115 (W × H1 × D) | |||
Main unit + Output socket + Dock | 257 × 401 × 115 (W × H2 × D) | |||
Main unit + Output socket shutter + Dock | 257 × 413 × 120 (W × H2 × D) | |||
Main unit + Output Cable + Dock | 257 × 387 × 115 (W × H2 × D) | |||
Mass | ||||
Mass (assembled charging station) | 3.4 kg to 7 kg | |||
Temperature | ||||
Operational | -25 °C to +85 °C | |||
Ambiental | -25 °C to +50 °C | |||
Storage | -30 °C to +85 °C |