Smart charging station for domestic and residential charging environments
Maximum charging power:
One-phase installation: 7.4 kW (1 × 32 A)
Three-phase installation: 22 kW (3 × 32 A)
Charging outlet type:
Type 2 socket
Type 2 tethered charging cable
Device power consumption: From 10 W to 15 W (highest measured value of full configuration)
Level of protection:
Impact protection: IK10 protection against external mechanical impacts to enclosure (by IEC 62262)
Ingress protection: IP56 protection against dust and liquid penetration (by IEC 60529)
Electrical protection:
DC fault current sensors 6 mA (default)
PEN protection (UK edition)
Other protection installed externally upstream
Communication technologies allow BEMS, cloud integration and ensure communication stability.
Connectivity
Wi-Fi – for WLAN connection
Bluetooth & Wi-Fi – for Smartphone mobile app connection
Sub-1 GHz – for wireless connection with Load Guard (when used)
EV communication:
IEC 61851
ISO 15118 – supported by design, not available at launch
Local communication protocols, Smart building integration: MQTT, Modbus RTU, OCPP
Cloud connection: OCPP (1.6 starting version)
RS-485 terminals for connection with an external meter
Energy meter:
embedded class 2 energy meter
can be connected with a MID compliant meter
Modes of charging:
Fast
Interactive
User identification: Smartphone app, RFID
User interface: LED and sound signals, press button, smartphone app
Material: Polycarbonate reinforced with glass fibers, TPE gasket
Colour: Light grey (RAL 7001)
Modularity – the charging station consists of three modules – enables simple and fast product delivery and installation:
Module 1 – Dock (Wallmount)
Module 2 – Output socket without shutter / Output socket with shutter / Output cable
Module 3 – Main unit
The charging station offers versatile connectivity options to suit various energy management systems:
integration with Local Energy Management System (LEMS)
integration with Cloud Energy Management System (CEMS)
standalone operation with Dynamic Load Management (DLM)
Setting up of the charging station, as well as FW upgrade, can be done locally or remotely, in compliance with the predefined security levels.
Charging station customization:
Encloser branding with laser printing
App branding
Access levels (when the top cover of the main unit is removed)
Load schedules and custom settings
...