Packaging

...

Figure 2: Label on the packaging

2. Product description

Basic Functionalities

...

Anchor
_Hlk47954260
_Hlk47954260
LTE module

Frequency bands:

LTE-FDD: B1 (2100 MHz), B3 (1800 MHz), B5 (850 MHz), B7 (2600 MHz), B8 (900 MHz), B20 (800 MHz)

LTE-TDD: B38 (2600 MHz), B40 (2300 MHz), B41 (2500 MHz)

WCDMA: B1 (2100 MHz), B5 (850 MHz), B8 (900 MHz)

GSM/EDGE: B3 (1800 MHz), B8 (900 MHz)

Transmitting power:

33dBm±2dB for GSM

24dBm+1/-3dB for WCDMA

23dBm±2dB for LTE-FDD

23dBm±2dB for LTE-TDD

LTE Router

Frequency bands:

4G (LTE-FDD): B1 (2100 MHz), B3 (1800 MHz), B5 (850 MHz), B7 (2600 MHz), B8 (900 MHz), B20 (800 MHz)

4G (LTE-TDD): B38 (2600 MHz), B40 (2300 MHz), B41 (2500 MHz)

3G: B1 (2100 MHz), B5 (850 MHz), B8 (900 MHz)

2G: B3 (1800 MHz), B8 (900 MHz)

Transmitting power:

21.9 dB

RFID module

Frequency band:

13.56 MHz (HF)

Transmitting power:

up to 8 dBm

Dimensions

...

Figure 4: Dimensions of INCH DUO charging station

Figure 5: Dimensions of INCH DUO power supply compartment

Anchor
_Toc15375580
_Toc15375580
Anchor
_Toc46302837
_Toc46302837
Anchor
_Hlk69808445
_Hlk69808445
Anchor
_Toc105675353
_Toc105675353
Optional and Extra Equipment

...

Power management of master charging station decides, based on information provided by Load Guard, what target current to set on its connector and other stations of the cluster. If necessary, it will increase or decrease the charging power or even stop it completely to prevent the fuses from switching off due to overcharging.

...

Figure 7: Load Guard

Etrel Ocean

Etrel Ocean is a complete software solution for scalable electric vehicle charging management that supports complete overview and control of charging stations while covering numerous use cases.

Usually, it is not needed for home use, its advantages are in the field of management of (real and virtual) clusters of charging stations. It is adaptable and configurable to different business cases.

...

Figure 8: Etrel Ocean

Anchor
_Toc61355904
_Toc61355904
Anchor
_Toc105675354
_Toc105675354
Identify Product Variant

...

Anchor
_Toc48636355
_Toc48636355
Anchor
_Toc105675355
_Toc105675355
Circuit Diagram

...

Anchor
_Toc48636356
_Toc48636356
Anchor
_Toc105675356
_Toc105675356
3. Operation and charging procedure

INCH DUO charging station can be controlled locally or remotely, through web interface, or through charging station management system. Configuration and usage of the charging station’s web interface is described in the next chapter.

...

Figure 24: Paying procedure in case of clusters, input of designation of charging station where charging was performed at another charging station with paying terminal

Anchor
_Toc48636361
_Toc48636361
Anchor
_Toc105675364
_Toc105675364

...

4. Charging station Web interface

Anchor
_Hlk21437075
_Hlk21437075
Anchor
_Toc48636370
_Toc48636370
Anchor
_Hlk15369812
_Hlk15369812
Charging station’s web interface allows the connection to the charging station platform, configuration of its settings as well as check of the charging session and station data, check of the connectivity status and errors description when they occur.

...

More information about the web interface can be found in the INCH DUO Configuration guide.

Anchor
_Toc105675373
_Toc105675373

...

5. Regular Maintenance

It is recommended to perform a visual check and test of the protection elements at least once per year if local regulations do not state otherwise. It is possible that the requirement is to check more often, e.g., every three months, or every month. The check should also be documented.

...

1

Measuring the voltage on all phases and between neutral and earth wires.

2

Measuring resistance between grounding and housing / door of the station.

3

Test of RCD protection 1 with the test button (in case of failure, change of RCD is required or removal of charging station from operation).

4

Test of RCD protection 2 with the test button (in case of failure, change of RCD is required or removal of charging station from operation).

5

Performance check: switch off all the main fuses and reboot of charging station.

6

Check-up of pins in socket 1 (no corrosion should be visible).

7

Check-up of pins in socket 2 (no corrosion should be visible).

8

Checking the socket 1 (socket should be free of dirt and foreign objects).

9

Checking the socket 2 (socket should be free of dirt and foreign objects).

10

Login with RFID card (if RFID authorization is enabled and online check is made).

11

Login with SMS (if SMS authorization is enabled and online check is made).

12

Login with mobile- app (if APP authorization is enabled and online check is made).

13

Start charging on socket 1 with a load (with EV or tester + load).

14

Display of power consumption on LCD display of the charging station for socket 1 (for this step approx. 5 minutes is needed).

15

Stop charging at socket 1.

16

Logout and re-login.

17

Start charging on socket 2 with a load (with EV or tester + load).

18

Display of power consumption on the screen for socket 2 (for this step approx. 5 minutes is needed).

19

Stop charging at socket 2.

20

Check-up of the mechanical condition of the housing and optional labels.

21

Check-up of the condition of LCD display (mechanical or other defects).

22

Verifying that the latest version of SW is loaded on the charger

23

Optional update if it is part of the product offer. (It can be implemented by Etrel locally or it can be done remotely from client’s back end).

Anchor
_Toc15375621
_Toc15375621
Anchor
_Toc32845371
_Toc32845371
Anchor
_Toc38381187
_Toc38381187
Anchor
_Toc48636378
_Toc48636378
Anchor
_Toc105675378
_Toc105675378

...

6. Troubleshooting

In the table below, all possible events that can occur at the power up of the station are listed with the procedure what to do in case something is wrong.

...

The reset of the charging station can be made from the web interface as well.

Anchor
_Toc48636379
_Toc48636379
Anchor
_Toc105675380
_Toc105675380

...

7. Contact Information

Technical support department

...