Tablef Contents
...
General Information
Intended Use
Note |
---|
Etrel INCH DUO charging station is intended only for charging of electric vehicles and should not be used to charge other appliances or for any other purpose. |
...
Anchor
No flammable materials or liquids should be used or stored in the direct vicinity of the charging station.
...
Different types of charging connectors and converters are available as a part of optional equipment to allow safe charging of any standard electric vehicle.
...
Safety Information
...
Operation
The device must be used in accordance with the instructions contained in this manual. _Toc48636347 Anchor
Do not operate charging station if there is visible damage to the unit or charging cable. Call manufacturers or reseller’s support department for advice how to proceed.
...
When the charging station without integral overcurrent device is installed, the proper overcurrent device should be installed in the main electrical cabinet.
...
...
Irregularity or Interference at Operation
In the event of irregularities or interference in the operation of the device, immediately stop using the charging station and inform the charging station operator of the situation by phone number located on the housing or other place.
...
Maintenance
Charging station can be maintained and repaired by qualified personnel only.
...
Avoid hazardous risks. Only the manufacturer, an authorized service technician, or technically qualified personnel may replace damaged charging station or its components.
...
Fire Safety Measures
At the location of car charging, the fire hazards and thus the threats are increased during the process of charging. The overall design of our products is made on the basis assumption that the fault could occur on any element of the system. Either in the electrical wiring of power supply, in wiring or inside of the charging station, or in the car.
...
Provision of suitable portable fire extinguisher at the location of the charging station is proposed.
...
...
Firefighting Measures
CHARGING STATION FIRE
In the event of a charging fire, the usual rules in the event of an electrical cabinet fire apply. In case of fire please follow these steps:
...
If the batteries catch fire, they will burn until they burn out completely. Another option is to immerse the batteries in water for at least half an hour. If the battery is not extinguished successfully, the fire will recur.
...
Environmental Safety Measures
When implementing protection measures, environmental protection must also be observed. For this reason, special care has been put into selection of the components and their compliance with the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS). This directive restricts use of hazardous materials in the manufacture of various types of electronic and electrical equipment.
...
Another example of use of environmentally friendly materials in our products is compliance to REACH, which is a regulation of the European Union, adopted to improve the protection of human health and the environment from the risks that can be posed by chemicals. REACH regulation also promotes alternative methods for the hazard assessment of substances to reduce the number of tests on animals. Packaging of our products is environmentally friendly and materials degradable.
...
...
Correct Disposal of this Product
Information about WEEE Directive
...
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
...
Compliancy
...
...
Simplified EU Declaration of Conformity
Hereby, Etrel d.o.o. declares that the radio equipment type INCH DUO is in compliance with Radio Equipment Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address:
...
Select "Access documentation" and then "Certificates".
...
...
Tested Compliancy with Standards
Etrel INCH DUO charging station was tested at accredited third-party laboratory SIQ - Slovenian Institute of Quality and Metrology. Performed tests cover all the requirements of RED, LVD and EMC directives of the European Union, according to the specifications of the following standards:
IEC 61851-1:2017 (EN IEC 61851-1:2019)
IEC 61851-21-2:2018
ETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V2.2.1
ETSI EN 301 489-52 V1.1.0
ETSI EN 301 489-3 V2.1.1
EN 60529:1991 + A1:2000 + A2:2013
EN 62262:2002
...
Safety Risk Analysis
...
All our charging stations are tested and proved compliant with EN 61851 Part 1, Part 21-2, and requirements of harmonized standards to fulfil RED, LVD and EMC directive. These tests and judgement of compliancy was performed by external accredited organization, SIQ - Slovenian Institute of Quality and Metrology, Mašera - Spasićeva ulica 10, 1000 Ljubljana, Slovenia, www.siq.si.
...
...
Design Considerations
Special care has been put into selection of components and materials and their compliance to requirements set in standards, technical directives, and rules of good practice.
...
The ingress protection class of IP54 proves, that the enclosure of the charging station is protecting the internals against ingress of solid objects, permits only limited ingress of dust and is protected against water splashes from all directions. Impact protection, of at least IK08 states, that the charging station can withstand impacts, equivalent to 1.7 kg dropped from height of 30 cm. As required, tests for the IK class were performed before testing of IP class.
...
...
Licenses
At the same location as the complete EU Declaration of Conformity, in the folder "Licenses", manifest file with information about versions and licenses of integrated software can be found.
...
INCH Duo:
No stacking, symbol:
...
Packaging
...
Figure 2: Label on the packaging
...
...
...
PRODUCT DESCRIPTION
...
Basic Functionalities
Etrel INCH DUO is a smart charging station that can predict EV charging habits and help charge the car by the time it is needed, at the lowest possible cost.
...
LCD Display
Figure 3: Etrel INCH DUO
...
...
...
Base Specifications
Input:
Anchor _Hlk47954176 _Hlk47954176 2x230/400V~; 3W+N+PE; 50/60 Hz; 32 AmaxOutput: 2x230/400V~; 3W+N+PE; 50/60 Hz; 32 Amax
Maximum charging power: two charging spots with 7,36 kW (single-phase) or 22,08 kW (three-phase).
Device power consumption:
...
Frequency bands: LTE-FDD: B1 (2100 MHz), B3 (1800 MHz), B5 (850 MHz), B7 (2600 MHz), B8 (900 MHz), B20 (800 MHz) LTE-TDD: B38 (2600 MHz), B40 (2300 MHz), B41 (2500 MHz) WCDMA: B1 (2100 MHz), B5 (850 MHz), B8 (900 MHz) GSM/EDGE: B3 (1800 MHz), B8 (900 MHz) Transmitting power: 33dBm±2dB for GSM 24dBm+1/-3dB for WCDMA 23dBm±2dB for LTE-FDD 23dBm±2dB for LTE-TDD | LTE Router Frequency bands: 4G (LTE-FDD): B1 (2100 MHz), B3 (1800 MHz), B5 (850 MHz), B7 (2600 MHz), B8 (900 MHz), B20 (800 MHz) 4G (LTE-TDD): B38 (2600 MHz), B40 (2300 MHz), B41 (2500 MHz) 3G: B1 (2100 MHz), B5 (850 MHz), B8 (900 MHz) 2G: B3 (1800 MHz), B8 (900 MHz) Transmitting power: 21.9 dB | ||||||
RFID module Frequency band: 13.56 MHz (HF) Transmitting power: up to 8 dBm |
Dimensions
...
Figure 4: Dimensions of INCH DUO charging station
Figure 5: Dimensions of INCH DUO power supply compartment
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
...
Power management of master charging station decides, based on information provided by Load Guard, what target current to set on its connector and other stations of the cluster. If necessary, it will increase or decrease the charging power or even stop it completely to prevent the fuses from switching off due to overcharging.
...
Figure 7: Load Guard
Etrel Ocean
Etrel Ocean is a complete software solution for scalable electric vehicle charging management that supports complete overview and control of charging stations while covering numerous use cases.
Usually, it is not needed for home use, its advantages are in the field of management of (real and virtual) clusters of charging stations. It is adaptable and configurable to different business cases.
...
Figure 8: Etrel Ocean
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
...
Set subnet mask to 255.255.255.0. and the pinging should work.
Figure 33: Change the IP of the computer and subnet mask
...
Choose TCP/IP. In the Configure IPv4 option choose Manual and change IPv4 Address to 192.168.1.1. Last bolded number can be a random number as long as it is different than 250 (used by station) and is not used by any other appliance in the network. Set subnet mask to 255.255.255.0. and the pinging should work.
Figure 37: Set network settings
...
hand screwdriver hexagon 2.5 mm,
tweezers,
unlock keys.
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
...